1. Connecting to z/OS console via Z and I Emulator for Windows 62x160 screen size results in error IEE938I

Problem
IEE936I CONSOLE HHSP0141 INITIALIZATION ERROR - RC:01 - 3277-2 IS ASSUMED is logged by z/OS console when using HCL Z and I Emulator for Windows version 6.0.2 with a 62x160 screen size.
Cause

z/OS console connection is being made through the OSA-ICC telnet server. This server does not support the Terminal Type of IBM-DYNAMIC.

APAR IC71220 changed the default Terminal Type string passed to the telnet server for screen sizes greater than 27x132.

Resolution
To use 62x160 screen size display sessions with OSA-ICC telnet servers, take the following steps:
  1. Edit the WS session profile.
  2. Add the following statements under the Telnet3270 stanza to force HCL Z and I Emulator for Windows to use the original default string:
    [Telnet3270]
    TerminalTypeString=IBM-3278-2-E